MCR295 H20 CATALOGUE MANU

  • MCR295 H20 CATALOGUE MANU
  • MCR295 H20 CATALOGUE MANU
  • MCR295 H20 CATALOGUE MANU
MCR295 H20 CATALOGUE MANU
  • Famous Global
  • Global
  • 5 to 50days
  • as u need units

Canada used Tower Crane, the United States used Tower Crane, Mexico used Tower Crane, Greenland used Tower Crane

 MCR295 H20 CATALOGUE MANU

 

Collect the Catalogue and Manu connect with us please.

 

Series , Luffing jib Crane, Topkit tower crane, Hammer head tower crane, Topless tower crane, Flat top tower crane,

Model,

Jib length,   m

Max load,   Ton

Tip load,    Ton

Type, Stationary , Inter climbing ,Travelling,

And other Famous brand, Model ,  Depend on the brand , Model Ability , Year , Height and etc u want.

We have large units store.  From 6Ton to 20Ton. Store and Service all over the world.

 

Mean time , We supply all the Spare Parts U may need as follow,

Masts Section ,  Anchor Frame, Collar ,Tie , Fixing angle , Cabin, Hoist mech. Trolley mech. Luffing Mech. Slewing Mech. Pulley and etc.

 

Tower Crane Knowledge sharing:

 

How to solve the problem of unloading failure of tower crane from two aspects of circuit and hydraulic circuit

When the tower crane is overloaded or overthrown, the failure of the electrical system or hydraulic system can lead to the failure of the unloading. How to check the circuit and liquid circuit to solve the problem.

MCR295 H20 CATALOGUE MANU

1. Check the circuit

The purpose of circuit detection is to check whether the torque limiter and limit switch can also transmit the electrical signal to the unloading solenoid valve when providing the alarm signal to the panel indicator light. If so, the unloading circuit will be connected to realize safe unloading; otherwise, the safe unloading will fail.

MCR295 H20 CATALOGUE MANU

2. Check the liquid route

Check the liquid path, first check the pipe layout, no error, and finally focus on the logic valve, the logic valve is suspected that the one-way valve spring is hard or the valve diameter is small, so that the unloading oil path back pressure is large, resulting in unblocked unloading oil path, unloading difficult. Therefore, when the pressure of an or bn port corresponding to the action is measured under the alarm state.

MCR295 H20 CATALOGUE MANU

It is found that the pressure is about 1MPa, while the pilot pressure of the main valve is only about 0.6mpa, which proves that the doubt is correct. It is the large back pressure in the logic valve that causes the unloading difficulty.

MCR295 H20 CATALOGUE MANU

 