L68B1 Mast Section Elevator technical knowledge - regular inspection and maintenance of elevator

05-12-2019

Regular inspection and maintenance of elevator:


L68B1 Mast Section:

http://www.towercranesupply.com/product/l68b1-mast-section-for-tower-crane-mastsL68B1 Mast Section




1. Before the inspection, obvious signboards shall be set at the entrance and exit of each floor;




2. Check the elevator operation recorded in the duty diary;




3. Check that the fluctuation of power supply voltage and full load operation voltage is not more than plus or minus 5%;



L68B1 Mast Section:

http://www.towercranesupply.com/product/l68b1-mast-section-for-tower-crane-masts

L68B1 Mast Section

4. Check whether the cables are stacked neatly in the cage and whether they are damaged;




5. Check whether the control and touch buttons have action policies;




6. Check whether the limit switch is safe and reliable;




7. Observe that the cage operation channel shall be free of obstacles;




8. Check the meshing clearance between gear and rack to ensure the side clearance is 0.2-0.3mm;




9. Check the oil leakage and add new oil if necessary;




10. If any part needs to be repaired, report to the relevant technical leader in time and then repair;




11. Record and date the problems found in the shift day.